LPC bus decoding analysis and triggering based on the Acute Emperor TL2236B+ logic analyzerTime:2017-03-27 Before we have mentioned in the article of decoding in the embedded system more and more serial bus to communicate with each other, and Acute PC -based logic analyzer for analysis in the serial bus has very comprehensive solutions, today we bring decoding analysis and trigger the LPC bus and no other solution on the market at present. Introduction of LPC LPC (Low Pin Count) interface, mainly connected to common low-speed devices: BIOS, serial port, parallel port, PS/2 keyboard and mouse, floppy disk controller, LPC bus is usually physically connected to the South bridge on the motherboard. The biggest advantage of the LPC ISA significant reduction of 25-30 pins compared to the previous ISA BUS signal, so a new interface specification to replace ISA BUS was published by Intel in 1997. Actual case tests: Our customers are listed companies. Our products are mainly desktop computers, laptops, ultrabooks and tablet computers. In the development and debugging process, the ultrabook will have a blue screen in less than a minute after starting up. According to the preliminary analysis of their engineers, they suspected that there was something wrong with LPC communication, but they didn't have the means to verify the test. They contacted us to use the Acute PC based logic analyzer for bus analysis, hoping to find the problem. Long record capture waveform is as follows: Use the SPECIAL LPC bus analysis function of the Acute PC Based Logic analyzer to set LPC parameters: LCLK: LPC data transfer Clock. Data Edge: Analyze Data when LCLK rising Edge or falling Edge is set. LFRAME: Identifies the start of each Frame transmission cycle or the use for interrupting Frame transmission. LAD[0-3] : Data bus is used to transmit commands, addresses and data. Show the Field in Report: Enable report filtering by simply checking the items to be displayed in the report window. After the bus is set up correctly, the Acute PC Based logic analyzer will display the bus information intuitively in two ways: 1. The BUS decoding bar (BUS) below the waveform 2. The BUS information bar at the bottom allows the customer to see all the information of the BUS at a glance, no matter which way. With the newly launched LPC bus triggering function, the signal can be further located in the required ADDR, DATA or even the Error Frame, and the stacked oscilloscope can be used to identify which link went wrong. The Acute PC based logic analyzer performed intuitive bus analysis, which replaced the engineer's manual decoding work and enabled the engineer to quickly find out the problem of the blue screen of the computer starting up. DATA:2A repeated occurrence, which was inconsistent with their design. From the above examples, we can see that the Acute PC based logic analyzer not only reduces the work of engineers, but also helps engineers to quickly find problems and solve the problems that have plagued engineers for a long time. With the newly launched LPC bus trigger function, the signal can be further positioned at the desired signal location. |