Sequid TDR Impedance Test Scheme (I)Sequid TDR Impedance Test Scheme (I) The realization of a wideband impedances controlled system presents a formidable challenge to the designers, manufacturers and quality assurance managers of the central electronic component, the printed circuit board (PCB). The challenge stems not from a lack of electromagnetic design knowledge, but also from the huge price pressures in the PCB industry: that is, the ideal RF (RF) substrate, which developers consider to be perfectly suited for the CLOCK rates in the GHz range, is barely used. In contrast, low cost FR4 materials with uneven dielectric constant (DC) throughout the substrate are often used. In addition, the synthesis of multilayer PCBS from core materials and semi-cured sheets often results in geometric asymmetry, further increasing the source of uncertainty. However, in order to meet specified tolerances, many PCB manufacturers provide a line impedance check service, which in turn requires additional impedance test boards. These test boards are usually located at the edge of the PCB and therefore only partially represent the characteristics of the actual transmission lines of interest that are distributed throughout the production panel. In the worst case, the test board under test may be within the specified range, but the actual transmission line of interest may not meet the requirements. In addition to special changes in materials and production processes, design parameter changes (such as changes in layers, too short distances to GND planes, PCB boundaries, or other transmission lines) also occur from time to time, resulting in intolerable transmission line impedance fluctuations. The result of impedance fluctuations is clock deterioration and intercode interference, which leads to unacceptable bit error rates and ultimately performance degradation and even system failures. The line impedance can be determined with high precision by time domain reflection method (TDR). TDR technology has been in use since the 1970s to detect faults in underground or undersea cables. FIG. 1 shows a block diagram of an impedance measuring device based on TDR technology. The TDR itself consists of only a voltage step generator and a wideband sampler with a data acquisition unit. Figure 1: Block diagram of an impedance measurement system based on TDR technology. The basic measurement is this: a voltage generator produces a step signal, which is transmitted through the adapter, cable, and probe to the device under test (DUT). When an interaction occurs over the entire length of the device under test, the signal undergoes partial reflection and is transmitted back to the detector, thus achieving a spatial measurement of the device's waveform impedance. Many people know this principle from radar applications, so TDR is often referred to as cable radar. The rise time TR of the step signal determines the spatial resolution, so it should be as short as possible (for the Sequid DTDR-65 tr≈ 65ps, so the spatial resolution is about 5mm). Synchronization between the generator and the sampler (whose analog input bandwidth is at least 10GHz) is critical for low-noise operations (i.e., dithering values of only a few Ps). Ideally, a "true through" sampler is used, without the need for an external signal separator or coupler. This benefit is obvious because wideband signal separators are usually resistive, increasing insertion loss and noise. Finally, a TDR instrument also has a data recording unit, which is usually implemented using a microprocessor or FPGA. High-frequency TDR devices normally do not use real-time sampling, but instead use sequential or random sampling. Like strobes, these devices rely on reasonable techniques to record periodic signals that change rapidly. Data processing and visualization tasks are typically performed on a PC and can be fully integrated into a high-end instrument or connected via USB or Ethernet. Measuring the alignment of objects to TDR is a demanding task. Differential impedance measurements, for example, must use highly accurate phase matching cables and probes. If this requirement is not met, even mode and odd mode conversions will reduce the measurement accuracy. In addition, the probe head should be designed to match the impedance of the device under test to achieve the highest possible accuracy. Different systems on the market In the increasingly fast digital world, the measurement of line impedance has been shown to be the most important TDR application. Figure 2 shows an example of such a spatially resolved measurement of a transmission line with no interference (green curve) and with interference (red curve). Only if all elements along the transmission path (including not only the etched line, but also the cable, connector, and even the terminal resistance in the integrated circuit) are impedance matched can the non-reflected signal be transmitted between the transmitter and receiver, thus achieving the highest bit rate. Therefore, impedance control is an important factor in evaluating the signal integrity of differential and single-terminal lines. Developers and manufacturers can choose from a wide variety of different types of differential TDR systems (DTDR) for impedance control: from the most cost-effective to the most expensive. Some of the leading measurement technology manufacturers offer high precision high end TDR systems. These systems can be found in the field of high-speed oscilloscopes and are generally combined with the necessary accessories, such as (D)TDR probes. These devices are ideal for measuring transmission systems up to 20Gbit/s and above. Yet impedance controls seem to be a niche market for high-end device makers. As a result, they do not offer dedicated industrial solutions, and potential users can quickly get lost in a myriad of common RF measurement technologies before reaching the ultimate "impedance measurement" goal. In addition, due to their high performance and versatility, all of these systems are in the high price domain, which makes the investment less attractive, especially if TDR is not in continuous use. Some TDRS with low generality can be found in the field of industrial and special product measurement technology. Specific standard procedures have been established in these areas over the past two decades. These devices and associated software are optimized for measuring the impedance of the test board and are deployed by many PCB manufacturers. However, these TDRS are not suitable for the design and testing of random transmission lines within a PCB because the lack of a suitable probe - and worse - the slow signal rise time TR results in too little signal bandwidth, which in turn allows characterization of lines with a minimum length of about 10cm. As a third version, there is also a "make it yourself" solution. There are a few very cost-effective (D)TDR devices on the market in this area. This further purchase of components (TDR probes and phase-adjusted cables) generally satisfies technical prerequisites. In such cases, however, appropriate software must be developed for data logging, error reduction, impedance calculations, and result archiving so that it can be questioned whether a solution originating from one source is ultimately more cost-effective and secure. Sequid GmbH initially developed high resolution and high precision TDR systems for fish quality determination. In collaboration with German PCB manufacturer Elekonta Marek GmbH, the existing basic technology was further developed into a very high performance system (Sequid DTDR-65) that can meet all the requirements of impedance control measurement. It is a highly stable differential time domain reflectometer suitable for differential and single-ended transmission line impedance measurements with rates up to 10Gbit/s. The instrument has a 65ps step signal generator, thus supporting high-resolution measurements of the test board and the actual circuit. In addition, the DTDR-65 has particularly good jitter performance (Jrms< 500FS), which is typically found in high-end devices. A software solution was developed to enable non-RF experts to successfully measure impedance. This solution includes not only basic functions, such as device control, but also visually actionable functions for displaying line impedance. The tolerance template makes it very simple to make a PASS/FAIL declaration. Here are some simple application examples. Figure 3 shows a reflection of the RG 405 coaxial cable with and without SMA connectors as per assembly specification (1) and as per assembly specification (2). Two kinds of RG 405 cable line impedance Z0 51.5 Ω material, the transition of connector area is very obvious. Capacitance drop (deformation towards low impedance) is visible in the case of the wrong connector installation. This effect occurs frequently when external and internal conductors are installed too close together (i.e., a capacitor is built). |